<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>18014</ErrorNumber>
<ErrorFamily>Laser</ErrorFamily>
<ErrorMessage>
LASER: Communications error: incomplete msg &lt;message&gt;
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The recorder should be reset.  If this does not help, the laser serial cable
should be replaced.  Since the only other option is to replace the laser, the
MPE should be replaced first.  If this doesn't help, this error is likely due to
a faulty laser controller. Note that the controller and the laser are matched
and therefore the controller cannot be replaced without replacing the laser.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reboot the Platesetter.  Contact Creo Service if rebooting does not help.
</text></DescriptionText>
</OperatorAction>
<Cause>
Confused laser controller
</Cause>
<Cause>
Faulty laser serial cable.
</Cause>
<Cause>
Faulty MPE
</Cause>
<Cause>
Faulty laser controller.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:48 2008 PST
</Updated>
<Links>
</Links>
</Error>